AMC 2026 catalogue

Test Instruments

Clamp Meters

Need a price? Log in or register at Grainger.ca 154

TEST INSTRUMENTS

Clamp Meters

Jaw Capacity

AC Response

Max. AC Amps

Max. AC Volts

Max. DC Amps

Max. DC Volts

Max. ohms Display Safety Rating Special Features

Item

No. Amprobe

1.0 in (25 mm) TRMS 300 600 300 — — LCD CAT III 600 V Backlit Display, DCA Zero, Maximizes Battery Life,

Non-Contact Voltage Detection (NCV) FETAMP25-1

1.0 in (25 mm) TRMS 600 600 — 600 40 LCD CAT III 600V

Dual Displays (Amp & Volt), Frequency Measurement,

Micro Amps Measurement for Testing Flame

Sensors, Rubber Over-Molded Case

FETACD14PLUS

1.0 in (25 mm) TRMS 600 600 — 600 40MΩ LCD CAT III 600V Continuity Beeper, Measures Frequency, Resistance and Capacitance, Rubber Over-Molded Case Absorbs Shock FETACD10PLUS

1.2 in (30 mm) TRMS 600 600 — 600 60,000 LCD CAT III 600V Amp Tip Function FETAMP210-1 1.4 in (36 mm) TRMS 600 600 600 600 60,000 LCD CAT III 600V Amp Tip Function FETAMP220-1 1.4 in (36 mm) TRMS 600 600 600 600 60,000 LCD CAT III 600V DC Micro Amps FETAMP320-1

1.8 in (46 mm) Average 300 600 — — 1000 Rotary

Scale CAT IV 600V Measures Voltage and Current Without

Batteries, Works Below 32° F FETRS3PRO

1.9 in (48 mm) Average 1,000 600 — — 1000 Rotary

Scale CAT IV 600V Measures Voltage and Current Without

Batteries, Works Below 32° F FETRS1007PRO

2.0 in (51 mm) TRMS 800 600 1000 600 40 LCD CAT III 600V

"Third Hand" Test Probe Holder, Easy to Read LCD Display,

Relative Zero ModeMAX Capture Function for Inrush

Current Measurements (30 Ms Response), Rubber

Over-Molded Case with Built-In Probes Storage

FETACDC100

2.0 in (51 mm) TRMS 800 600 1000 600 40 Backlit CAT III 600V

Continuity Beeper, Max Capture Function Measures Inrush Current (30 Ms Response), Relative Zero Mode, Rubber Over-Molded Case

Absorbs Shock and Provides Built-In Probe Storage, True-RMS

FETACDC100TRMS

2.0 in (51 mm) TRMS 1,000 1,000 1000 10,000 60,000 LCD CAT IV 600V, CAT III 1,000V Amp Tip Function FETAMP330-1

Extech

0.9 in (23 mm) Average 30 400 30 400 — LCD CAT III 300 V Fast 40 Segment Bargraph, Min/Max, Data Hold, Auto Power

Off, One touch Auto Zero for DC Current measurements EXT380942

1.2 in (30 mm) TRMS 600 750 600 1,000 60 MΩ LCD CAT III 600 V

1.18" (30mm) jaw size accomodates conductors up to 350MCM, 6000 count backlit LCD display with bargraph, Built-in LED flashlight, Built-in non-contact voltage detector (NCV), DC Zero

mode, Data Hold, Min/Max, Relative function, Auto Power Off,

Inrush mode, Low Impedance (LoZ), Low Pass Filter (LPF)

EXTEX655

1.3 in (33 mm) TRMS 400 600 400 600 40MΩ LCD CAT III 600 V

8 to 1 Distance to Target Ratio, Built-In Non-Contact IR Thermometer with Laser Pointer for Locating Hot Spots (up

to 518 Degrees F/270 Degrees C), DC micron A Multimeter

Function for HVAC Flame Rod Current Measurements,

Dual Type K Thermocouple Input with Differential Temperature Function (T1, T2, T1-T2), True-RMS

EXTEX623

1.8 in (46 mm) TRMS 1,000 600 1000 600 40MΩ Backlit CAT III 600 V

4000 count backlit display, Autoranging, Data Hold and Min/Max, Auto Power off, Non-contact InfraRed

Temperature measurements, Peak hold

EXTEX820

1.8 in (46 mm) TRMS 1,000 1,000 1000 1,000 40MΩ Backlit CAT III 600 V Data Hold and Min/Max, DC Zero, Auto Power off, Non-

contact InfraRed Temperature measurements EXTEX830

1.8 in (46 mm) TRMS 1,000 1,000 1000 1,000 40MΩ LCD CAT III 600 V

4000 count backlit display, Autoranging, Data Hold and Min/Max, Auto Power off, Non-contact InfraRed

Temperature measurements, Peak hold

EXTEX830NIST

1.8 in (46 mm) TRMS 1,000 1,000 1000 1,000 40MΩ Backlit CAT IV 600V

4000 count backlit display, Autoranging, Data Hold and Min/Max, Auto Power off, Non-contact InfraRed

Temperature measurements, Peak hold

EXTEX840

2.0 in (51 mm) TRMS 1,500 750 1,500 1,000 40MΩ LCD CAT I V 600V

2.0" (52mm) jaw size for conductors up to 500MCM, Built-in non-contact Voltage detector with LED alert, Data Hold, Peak Hold, MIN/MAX, Auto Power Off, Dual 40,000/4000

count, backlit LCD display, Inrush function, Relative

Mode for Capacitance Zero and Offset Adjustment

EXTMA1500

15⁄16 in TRMS 400 — 400 — — LCD CAT III 300V Fast 40 Segment Bargraph, Min/Max, Data Hold

and Auto Power Off, One Touch Auto Zero EXT380947

21⁄32 in Average 200 — 200 — — Backlit

LCD CAT III 300V

0.7" (18mm) Jaw Opening, 2000 Count LCD Display, Autoranging with Auto Power Off and Data hold function,

Built-in white LED flashlight, Non-contact AC Voltage

detector (120/240VAC, 50/60Hz) via clamp tip

EXTMA120

1⁄2 in Average 80 600 80 600 40MΩ LCD CAT III 600V Extra-small diameter jaw designed to reach into very small areas EXT380950 Fluke

— — — — — 1,000 — LCD — Source/Simulate 4 to 20 mA and Source DC

Voltage to Test Voltage Input Devices FET773

Greenlee

1 3⁄16 in Yes 600 600 10 600 60 K LCD — Two Voltage Detection Modes - Non-

Contact or Using a Single Test Lead GLECM860

IDEAL

1.4 in (36 mm) Average 660 750 660 1,000 999.9 4 Digit LCD

CAT IV 600V, CAT III 1,000V TightSight™ Bottom Display WWG6XAA7

1.5 in (38 mm) Average 600 600 600 600 40 LCD CAT III 600V Low Battery Indicator WWG3EVP5

AMPROBE, EXTECH, FLUKE, GREENLEE, IDEAL

GLECM860 FETAMP25-1 WWG6XAA7 FETRS1007PRO EXT380942 EXTEX820