AMC 2026 catalogue

Pumps

Self-Priming and Chemical-Resistant Pumps

Find even MORE at Grainger.ca 1639

1-888-602-0000 PUMPS

Self-Priming Lawn Sprinkler/Booster Pumps

▪Cast-iron housings Pumps hold prime for efficient water transfer. WWG1N437 GGM5RWG8

HP Inlet Size Outlet Size

Best Efficiency

GPM @ Head Max. Head Voltage Amps Brand

Item

No. Open Dripproof

1 1 1⁄2 in NPT 1 1⁄2 in NPT 50 @ 55 ft. 118 ft. 120/240 VAC 16.2/8.1 Goulds Water Technology WWG1N440 1 1⁄2 1 1⁄2 in NPT 1 1⁄2 in NPT 50 @ 92 ft. 122 ft. 120/240 VAC 21.4/10.7 Goulds Water Technology WWG1N439 2 1 1⁄2 in NPT 1 1⁄2 in NPT 65 @ 97 ft. 125 ft. 208 - 240/480 VAC 6.8-6.4/3.2 Goulds Water Technology WWG1N437 2 1 1⁄2 in NPT 1 1⁄2 in NPT 65 @ 97 ft. 125 ft. 240 VAC 12.9 Goulds Water Technology WWG1N438 3 1 1⁄2 in NPT 1 1⁄2 in NPT 70 @ 102 ft. 129 ft. 240 VAC 13.3 Goulds Water Technology WWG1N436 Totally Enclosed Fan-Cooled

1⁄2 1 1⁄2 in NPT 1 1⁄2 in NPT 33 @ 55 ft. 80 ft. 208 - 240/480 VAC 3.8-3.5 /1.8 Dayton GGM5RWH7 3⁄4 1 1⁄2 in NPT 1 1⁄2 in NPT 26 @ 46 ft. 90 ft. 208 - 240/480 VAC 5.2-5.0/2.5 Dayton GGM5RWH8 1 1 1⁄2 in NPT 1 1⁄2 in NPT 32 @ 69 ft. 101 ft. 208 - 240/480 VAC 7.0-6.5/3.3 Dayton GGM5RWH9 1 1⁄2 1 1⁄2 in NPT 1 1⁄2 in NPT 35 @ 69 ft. 115 ft. 208 - 240/480 VAC 7.5-7.2/3.6 Dayton GGM5RWG8 2 1 1⁄2 in NPT 1 1⁄2 in NPT 42 @ 80 ft. 173 ft. 208 - 240/480 VAC 9.7-9.1/4.6 Dayton GGM5RWJ0 2 1 1⁄2 in NPT 1 1⁄2" NPT 42 @ 80 ft. 124 ft. 120/208 to 240V AC 26.2/13.6 -13.1 Dayton GGM5RWG9 3 1 1⁄2 in NPT 1 1⁄2" NPT 38 @ 119 ft. 177 ft. 208 to 240/480V AC 12.0-10.6/5.3 Dayton WWG5RWH3 7 1⁄2 2 in NPT 2" NPT 85 @ 117 ft. 180 ft. 208 to 240/480V AC 20.6-18.8/9.4 Dayton GGM5RWH5

DAYTON, GOULDS WATER TECHNOLOGY

High-Volume Chemical-Resistant Centrifugal Pumps and Pump Heads

▪Max. case working

pressure: 150 psi ▪Temp. range: 40° to 200°F ▪Max. viscosity: 31 SSU ▪Discharge ports rotate

in 90° increments

GGM5WXT4

HP Voltage Amps Phase Inlet Outlet

Max. GPM

@ Head

Best Efficiency

GPM @ Head

Min. GPM

@ Head Max. Head

Item

No. 1⁄3 115/230 6.8/3.4 Single 3⁄4" NPT 1⁄2" NPT 21 gpm @ 5 ft. 10 gpm @ 26 ft. 1 gpm @ 40 ft. 48 ft. GGM5WXR9 1⁄2 115/230 7.5/3.8 Single 3⁄4" NPT 3⁄4" NPT 38 gpm @ 5 ft. 28 gpm @ 22 ft. 5 gpm @ 40 ft. 50 ft. GGM5WXT0

3⁄4 115/230 9.0/4.5 Single 1 1⁄4" NPT 3⁄4" NPT 58 gpm @ 5 ft. 30 gpm @ 41 ft. 3 gpm @ 60 ft. 62 ft. GGM5WXT2 208-230/460 3.8-3.4/1.7 Three 1 1⁄4" NPT 3⁄4" NPT 58 gpm @ 5 ft. 30 gpm @ 41 ft. 3 gpm @ 60 ft. 62 ft. GGM5WXT3

1 115/230 13.0/6.5 Single 1 1⁄2" NPT 1 1⁄4" NPT 90 gpm @ 5 ft. 48 gpm @ 40 ft. 8 gpm @ 60 ft. 65 ft. GGM5WXT4 208-230/460 5.3-5.0/2.5 Three 1 1⁄2" NPT 1 1⁄4" NPT 90 gpm @ 5 ft. 48 gpm @ 40 ft. 8 gpm @ 60 ft. 65 ft. GGM5WXT5

1 1⁄2 115/230 15.0/7.5 Single 1 1⁄2" NPT 1 1⁄4" NPT 116 gpm @ 5 ft. 50 gpm @ 48 ft. 13 gpm @ 60 ft. 65 ft. GGM5WXT6 208-230/460 7.0-6.6/3.3 Three 1 1⁄2" NPT 1 1⁄4" NPT 116 gpm @ 5 ft. 50 gpm @ 48 ft. 13 gpm @ 60 ft. 65 ft. GGM5WXT7

2 115/230 18.0/9.0 Single 2" NPT 1 1⁄2" NPT 130 gpm @ 5 ft. 55 gpm @ 50 ft. 24 gpm @ 60 ft. 68 ft. GGM5WXT8 208-230/460 9.6-9.2/4.6 Three 2" NPT 1 1⁄2" NPT 130 gpm @ 5 ft. 55 gpm @ 50 ft. 24 gpm @ 60 ft. 68 ft. GGM5WXT9 3 230 14.5 Single 2" NPT 1 1⁄2" NPT 150 gpm @ 5 ft. 90 gpm @ 48 ft. 38 gpm @ 70 ft. 81 ft. GGM5WXU0

DAYTON

Designed for continuous-duty high-flow applications, including chemical processing, liquid transfer, cooling, and circulating. Pumps are straight centrifugal and feature a 304 stainless steel impeller and impeller nut. Other wetted materials include carbon, ceramic, and Viton®. 1-phase motors are capacitor-start, with automatic thermal reset protection and ball bearings. Pump heads require a NEMA 56J motor or 56J pump pedestal with appropriate motor.

Notes: Not recommended for trichloroethylene.

3-phase units require a pump control box, sold separately.

GGM2YEU4

Chemical-Resistant Centrifugal Pumps

▪Motors are 3450 rpm with NEMA 56J frame ▪Max. temp.: 140°F polypropylene, 180°F Noryl®

▪Max. viscosity: 100 SSU ▪1 1⁄2" ports Close-coupled pumps feature continuous-duty motors and resist most acids, alkalis, and inorganic solvents. Pump housing has seal flush ports to decontaminate the seal and seat elastomers.

Note: 3-phase units require a pump control box, sold separately.

HP Required

Best Efficiency GPM @ Head (Ft.) Max. Head (ft.) Housing Material Impeller Material Impeller Type Inlet Outlet ItemNo. Pedestal Pump

3⁄4 23 @ 41 72 Polypropylene Polypropylene Closed 1 1⁄2" 1 1⁄2" GGM2YEU8 1 38 @ 50 78 Noryl™ Noryl™ Closed 1 1⁄2" 1 1⁄2" GGM2YEX2 1 38 @ 50 79 Polypropylene Polypropylene Closed 1 1⁄2" 1 1⁄2" GGM2YEU9 1 1⁄2 54 @ 55 89 Polypropylene Closed 1 1⁄2" 1 1⁄2" GGM2YEV1 1 1⁄2 54 @ 55 82 Noryl™ Noryl™ Closed 1 1⁄2" 1 1⁄2" GGM2YEX3 2 58 @ 60 91 Polypropylene Polypropylene Closed 1 1⁄2" 1 1⁄2" GGM2YEV2 3 73 @ 60 86 Noryl™ Noryl™ Closed 1 1⁄2" 1 1⁄2" GGM2YEX5 3 73 @ 60 95 Polypropylene Polypropylene Closed 1 1⁄2" 1 1⁄2" GGM2YEV3

Material Content Code Seal Material For Use With Max. Temp. (F) Min. Temp. (F) Item No. Replacement Pump Shaft Seal

VXRXR Silicon Carbide, Viton Noryl Pumps 180 40 GGM3ACF1 VCRJR Carbon, Ceramic, Viton Noryl Pumps 180 40 GGM3ACE9 VCRJR Carbon, Ceramic, Viton Poly Pumps 180 40 GGM3ACF3 VXRXR Silicon Carbide, Viton Poly Pumps 180 40° GGM3ACF2

HP Voltage Phase Amps Max. GPM @ Head

Best Efficiency

GPM @ Head Min. GPM @ Head Max. Head Motor Enclosure

Item

No. Centrifugal Pump

1⁄3 115/208-230 Single 8.0/3.5-4.0 22 gpm @ 10 ft. 18 gpm @ 30 ft. 2 gpm @ 60 ft. 62 ft. Totally Enclosed Fan Cooled GGM2YEV4 1⁄2 208-230/460 Three 1.8-1.7/0.9 26 gpm @ 10 ft. 20 gpm @ 35 ft. 9 gpm @ 60 ft. 68 ft. Open Drip Proof GGM2YER4 1⁄2 208-230/460 Three 1.7-1.6/0.8 26 gpm @ 10 ft. 20 gpm @ 35 ft. 9 gpm @ 60 ft. 68 ft. Totally Enclosed Fan Cooled GGM2YEV6 2 115/208-230 Single 16.6/9.4-8.3 96 gpm @ 10 ft. 58 gpm @ 60 ft. 31 gpm @ 80 ft. 83 ft. Totally Enclosed Fan Cooled GGM2YEW4 3 230 Single 12.5 123 gpm @ 10 ft. 80 gpm @ 60 ft. 48 gpm @ 80 ft. 86 ft. Totally Enclosed Fan Cooled GGM2YEW6 3 230 Single 12.5 123 gpm @ 10 ft. 80 gpm @ 60 ft. 48 gpm @ 80 ft. 86 ft. Totally Enclosed Fan Cooled GGM2YEU4

DAYTON

GGM2YEU8