AMC 2026 catalogue

HVAC & Refrigeration

Commercial/Industrial-Duty Air Curtain Cabinets

Need a price? Log in or register at Grainger.ca 1880

HVAC & REFRIGERATION

GGE6E815

Commercial/Industrial-Duty Air Curtain Cabinets Modular cabinets accept any of the blowers on this page, and may be mounted in series to accommodate openings from 3 to 12 ft. wide. A 96"-wide door, for example, would use two 48"-wide air curtains. A complete air curtain consists of 1 air curtain cabinet and 1 blower. ETL Listed.

Note: Find information on Air Curtains and Accessories at Grainger.ca and search for “air curtains”.

GGE6E825

Width Height Depth

Item

No. Painted Steel

36 in

15 3⁄4 in 13 in

GGE6E826 38 in GGE6E825 42 in GGE6E824 48 in GGE6E823 60 in GGE6E822 Stainless Steel

36 in 15 3⁄4 in 13 in GGE4YN98 48 in GGE4YN99

DAYTON

Blowers for Air Curtain Cabinets Installation in air curtain cabinet requires no tools, just wing nuts and quick disconnect. All blowers fit Dayton air curtain cabinets, Nos. GGE6E822 to GGE6E826, No. GGE4YN98, and No. GGE4YN99. Multiple use allowable with up to 3 cabinets in series. ETL Listed.

Note: Find information on Air Curtains and Accessories at Grainger.ca and search for “air curtains”.

Motor HP Air Velocity

Air Delivery

with 36-In.

Cabinet

Air Delivery

with 38-In.

Cabinet

Air Delivery

with 42-In.

Cabinet

Air Delivery

with 48-In.

Cabinet

Air Delivery

with 60-In.

Cabinet Max. Amps Max. RPM

Max. Mounting

Height Voltage Hz Phase

Item

No. 1⁄4 hp 4,650 fpm 2,025 CFM 2,025 CFM 2,360 CFM 2,700 CFM 3,375 CFM 3.4 1,100 RPM 8 ft. 115 60 1 GGE6E821 1⁄2 hp 3,800 FPM 3,075 CFM 3,250 CFM 3,600 CFM 4,100 CFM 5,130 CFM 1.5/0.75 1,450 RPM 10 ft 208-230/460 60 3 GGE6E817 1⁄2 hp 4,850 fpm 3,075 CFM 3,250 CFM 3,600 CFM 4,100 CFM 5,130 CFM 5.2 1,745 RPM 10 ft 115 60 1 GGE6E820 3⁄4 hp 4,850 fpm 3,930 CFM 4,150 CFM 4,585 CFM 5,240 CFM 6,550 CFM 7.8 1,480 RPM 12 ft. 115 60 1 GGE6E819 1 hp 5,250 FPM 3,930 CFM 4,150 CFM 4,585 CFM 5,240 CFM 6,550 CFM 3.4/1.75 1,725 RPM 12 ft. 208-230/460 60 3 GGE6E816 1 1⁄2 hp 5,900 FPM 4,748 CFM 5,050 CFM 5,575 CFM 6,375 CFM 7,965 CFM 3.5/1.95 3,450 RPM 14 ft 208-230/460 60 3 GGE6E815

DAYTON

Dayton® Commercial/Industrial-Duty Air Curtain Selection Guide

Because no single air curtain cabinet is 100"W, use 1 No. GGE6E822 (60") and 1 No. GGE6E824 (42") to span a 100"W opening. It is acceptable for cabinets to be slightly wider than the opening. Each cabinet requires a blower assembly. Use Table A to determine the horsepower (HP) of the blower required for your air curtain cabinet. Blower HP is determined by mounting height, purpose of the air curtain (thermal barrier, etc.), and the wind speed that the air curtain is expected to neutralize. For extreme conditions

* Complete air curtain; see below for specifications.

HP 120V 1 Ph 208-230/460V 3 Ph Table B: Determine Blower Model No.

1⁄10 4HZ94 * — 1⁄8 4YP01 * — 1⁄8 4HZ95 * — 1⁄8 4YP02 * — 1⁄4 6E821 — 1⁄2 6E820 6E817 1 — 6E816 1 1⁄2 — 6E815

Wind Speed Thermal Barrier Insect Control Walk-In Cooler Walk-In Freezer (mph) 8 ft. 10 ft. 8 ft. 10 ft. 8 ft. 10 ft. 8 ft. 10 ft. Table A: Determine Blower HP @ Mounting Height (ft.)

5 1⁄10 to 1⁄8 1⁄2 1⁄2 3⁄4 1⁄4 1⁄2 1⁄2 3⁄4 8 1⁄4 1⁄2 to 3⁄4 1⁄2 3⁄4 — — — — 12 — — 3⁄4 1 — — — — 15 — — 1 1 1⁄2 — — — —

(gusty winds or heavy insect control), select a blower HP 1 size larger than what the table recommends. Indoor installations assume a wind speed of 5 mph, unless otherwise specified. After selecting the HP for your application, use Table B to find the blower stock number that matches the available electrical power. See this page for complete electrical specifications for each blower. Air curtain overlap of door openings is acceptable.

Blower Selection Example Assume a 10-ft.-high x 100"-wide opening into a walk-in cooler, and an available 120V, 1-phase electrical circuit to operate the air curtain. In Table A, find Walk-In Cooler. In column labeled 10 ft., find 1⁄2 HP across from 5 mph wind speed (indoor installations assume 5 mph). Knowing that a 1⁄2-HP blower is required, use Table B to find 2 possibilities: No. GGE6E820 and GGE6E817. Select 2 No. GGE6E820 blower assemblies (120V, 1-phase), 1 for each cabinet.