AMC 2026 catalogue

Electrical

Timers

Find even MORE at Grainger.ca 113

1-888-602-0000 ELECTRICAL

Timer Replacement Motors Replacement Motors

WWG1PNK1

Description/Special Features For Use With

Item

No. 125V T100, T170, T180, T100R201, T100R301, WH30, and WH40 Series Timers WWG1PNK1 208 to 277V, Tolerance of Plus/Minus 10% T100, T170, T180, T100R201, T100R301, WH30, and WH40 Series Timers WWG1PNK2

INTERMATIC

Plug-in Timers

▪125VAC

GUS45KM66

Features Voltage Amps Watts Min. Time Setting Max. Time Setting

Max. On/ Off Cycles Receptacle Type Colour

Item

No. Digital

7 Day Programming, Manual Daylight Savings, Battery Backup 125V AC 15 1800 1 min 7 day 20 (2) 5-15R White GUS45KM66

Automatically Turn On/Off Outdoor Lighting and

Saves Energy by Switching Off Lights at Night 120V AC — 1000 1 min 23 hr, 59 min 24 5-15R Black GUS45MW07

Battery Backup, Manual Daylight Savings 125V AC 15 1800 1 min 7 day 20 (2) 5-15R White NSI455E Automatically Turn On/Off Outdoor Lighting and

Saves Energy by Switching Off Lights at Night 120V AC 15 1000 1 min 59 min 23 hr 24 5-15R Black NSI642E

Mechanical

WP Plg In 24 Hr. 2 Grounded Outlet B, 125V, 15A 120V AC 15 500 30 min 30 min 23 hr 24 5-15R Black NSI602B

TORK

Vertical-Mount Liquid Level Switches These float switches mount in the top and/or bottom of a tank or vessel to actuate High/Low alarms, control relays, PLC’s, or other low power devices. Encapsulated, magnetic dry contact reed switches can deliver more than 5 million switching cycles at rated electrical loads. On select models, operation can be changed to be Normally Closed or Normally Open (dry, empty tank conditions) by removing and flipping the floats. During installation, Adjustable Vertical models can be set lower by up to 2", or higher by up to 69". WWG4YM35 WWG3AY51 WWG2ZY89 WWG2A551

Item

Tank Connection

Size

VA Rating

Operating

Temp. Range

Max. Pressure

Switch Function

Overall Length Float Material

Float Length

Float

Dia. Stem Material

Stem Length Brand

Item

No. Vertical Open Tank

Liquid Level Switch

1⁄8 in NPT 30 221°F max 100 psi Selectable 2.25 in Polypropylene 1.00 in 1.00 in Polypropylene 1.63 in Madison WWG2A554 1⁄4 in NPT 60 392°F max 200 psi Selectable 3.38 in Stainless Steel 2.00 in 2.13 in Stainless Steel 2.63 in Madison WWG2A551 Vertical Adjustable

Liquid Level Switch 2 in NPT 60 392°F max 200 psi Selectable 12.00 in 316 Stainless Steel 2.00 in 2.13 in 316 Stainless Steel 10.50 in Madison WWG2ZY89

Vertical

Liquid Level Switch

1⁄8 in NPT 30 221°F max 150 psi Selectable 2.25 in Buna N 1.00 in 1.00 in PBT 1.63 in Madison WWG4YM35

30 392°F max 300 psi Selectable 2.25 in 316 Stainless Steel 1.19 in 1.13 in 316 Stainless Steel 1.63 in Madison WWG4YM31

1⁄4 in NPT

60 221°F max 100 psi Selectable 3.38 in Polypropylene 2.00 in 1.50 in Polypropylene 2.63 in Madison WWG2A552 60 150 psi Selectable 3.38 in Buna N 2.00 in 1.25 in Brass 2.63 in Madison WWG2A553 60 482°F max 200 psi Selectable 3.38 in 316 Stainless Steel

2.00 in 2.13 in 316 Stainless Steel

2.63 in Madison WWG2ZY27 100 392°F max 500 psi Selectable 3.38 in 2.00 in 2.00 in 2.63 in Madison WWG4YM33

Multi-level Liquid Level Switch

1⁄2 in NPT 60 200 psi Open on Rise 8.25 in 2.00 in 2.13 in 7.25 in Madison WWG3AY51

2 in NPT 60 221°F max 100 psi Selectable Adjustable, up to 36 in Polypropylene 2.00 in 1.50 in Polypropylene Adjustable Madison WWG3VU49

60 150 psi Selectable Adjustable, up to 36 in Buna N 2.00 in 1.25 in Brass Adjustable Madison WWG3VU48

Side

Alternator Tank Liquid Level Switch

2 1⁄2 in MNPT

-22° to

220°F

50 psi Close on Rise 13.84 in

Stainless Steel

7.0 in 2.5 in

Stainless Steel

4.0 in Telemecanique Sensors SQD9038CG31 — 50 psi Close on Rise 13.84 in 7.0 in 2.5 in 4.0 in Telemecanique Sensors SQD9038CG32 — 50 psi Close on Rise 13.84 in 7.0 in 2.5 in 4.0 in Telemecanique Sensors SQD9038CG36

Tank Liquid Level Switch

— 50 psi Close on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG30 — 50 psi Close on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG31 — 50 psi Close on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG32 — 50 psi Close on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG33 — 50 psi Open on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG33R — 50 psi Close on Rise 14.66 in 7.13 in 2.58 in 3.89 in Telemecanique Sensors SQD9037HG34 — 50 psi Close on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG35 — 50 psi Close on Rise 16.06 in 7.13 in 2.58 in 5.07 in Telemecanique Sensors SQD9037HG37 Open Tank

Alternator Open Liquid Level Switch —

460V AC

-22° to

220°F

— Close on Rise 11.8 in — — —

— Telemecanique Sensors SQD9038AG1 460V AC — Close on Rise 10.32 in

Stainless Steel

7.0 in 7.0 in — Telemecanique Sensors SQD9038AG1C 460V AC — Close on Rise 11.8 in 7.0 in 7.0 in — Telemecanique Sensors SQD9038AW1 Open Liquid Level Switch

460V AC — Open on Rise 7.1 in 7.0 in 7.0 in — Telemecanique Sensors SQD9036DG2R 475V AC — Close on Rise 7.1 in 7.0 in 7.0 in — Telemecanique Sensors SQD9036DW31

MADISON, TELEMECANIQUE SENSORS