Analog Multimeters

Analog display provides a quick visual status check. Each includes test leads and batteries. Simpson Instrument accuracy: VAC ±3% full scale, VDC ±2% full scale accuracy.

WWG1TC62 WWG1A587 Item For Use With Connection Item No. Test Lead Kit Mfr. No. 260-6LXPM, 260-8XI Right Angle Plug to Probe WWG23MM52

Max. AC Volts Max. DC Amps

Audible Continuity

Overload Protector

(Reset) Max. ohms Decibels (dB)

Mirrored

Scale

Item

No.

1,000 10 A No No 20 MΩ -20 to +50 Yes WWG1A587 10 A Yes Yes 20 MΩ -20 to +50 Yes WWG1T848 10 A Yes Yes 20 MΩ -20 to +50 Yes WWG1TC62

SIMPSON ELECTRIC

True RMS Current vs. Inrush Current TRUE RMS

▪“RMS” (root mean square) comes from a

formula that calculates the effective value (or heating value) of any AC wave shape ▪Electrical components such as fuses, bus

bars, conductors, and circuit breakers are rated in RMS current because their main limitation has to do with heat dissipation ▪When checking an electrical circuit

for overloading, the RMS current is measured and compared to the rated value for the component in question ▪For circuits with AC and DC components

or distorted signals, a meter with an AC+DC function is used

INRUSH

▪Fluke® clamps' proprietary inrush

(starting) measurement takes a large number of samples at the beginning of the starting current, then digitally filters and processes the samples to calculate the actual starting current ▪Measure starting current in the

same manner as an overcurrent protection device ▪More accurate than slower min./

max. functions that can miss the event partially or completely

Clamp Meters, Modules, and Kits

200 max. AC amp meter jaw detaches for easy access to wires. Meters with 1,400 max. AC amps offer average function via display hold. Wireless clamp meter module kit includes a clamp meter, test leads, alligator clips, an AC clamp, batteries, a soft case, and an information pack.

Max. AC Amps Max. DC Amps Max. AC Volts Max. DC Volts AC Response Max. ohms Inrush Data Hold Diode Test Jaw Capacity

Item

No. Digital Clamp Meter

200 200 600 600 TRMS 6,000 — Yes — 0.7 in (17 mm) FET365 400 — 600 600 TRMS 4,000 — Yes — 1.1 in (28 mm) FET323 400 — 600 600 TRMS 4,000 — Yes No 1.1 in (28 mm) FET324 400 400 600 600 TRMS 40,000 — Yes No 1.1 in (28 mm) FET325 400 — — — TRMS — Yes No No 1.3 in (33 mm) FETA3000FC 600 1000 — — 45 Hz to 1 kHz — — Yes No 1.2 in (30 mm) FETA3002FC 600 600 1,000 1,000 800 Hz 6,000 Yes Yes No 0 in to 1 5⁄8 in FETFLK374FC 600 600 1,000 1,000 800 Hz 60,000 Yes Yes No 0 in to 1 5⁄8 in FETFLK375FC 600 200uA 600 600 TRMS 60,000 No Yes No 0 in to 1 5⁄8 in FET902FC 1,000 1000 1,000 1,000 800 Hz 60,000 Yes Yes No 0 in to 1 5⁄8 in FETFLK376FC 1400 400 1,000 1,000 TRMS 400 Yes Yes — 2.9 in (74 mm) FET353 1400 400 1,000 1,000 TRMS 400 Yes Yes Yes 2.9 in (74 mm) FET355 2500 999.9 1,000 1,000 TRMS 60,000 Yes Yes — 1.4 in (36 mm) FET381 No Range 2000 999 1,000 No — No No No 2.5 in (64mm) FETFLKA3003FC No Range 99.9mA 30 30 No — No No No 0.2 in (5 mm) FETFLKA3004FC

FLUKE

Fluke 370 Clamp Meter

▪1.3" jaw capacity ▪750 MCM max.

conductor size ▪Designed for stable

readings in noisy electrical environments ▪Backlit LCD

Fluke 381 Clamp Meter

▪1.4" jaw capacity ▪751 MCM max.

conductor size ▪Remote display with

flexible current probe ▪Removable magnet ▪Backlit LCD

FC Wireless Basic Kit with I3000

▪Clamp meter, test leads,

alligator clips, current module, iFlex coil, batteries, soft case, and information pack ▪Min./Max./Average memory

FETA3000FC

Max. AC Amps AC Response Inrush Data Hold Jaw Capacity Includes

Item

No. Digital Clamp Meter

400 TRMS Yes No 1.3 in (33 mm) AC Clamp, Alligator Clips, Clamp Meter, Information Pack, Soft Case, Test Leads FETA3000FC-KIT

Wireless Clamp Meter Kit

2500 TRMS Yes No 10.0 in (254 mm) AC175 Alligator Clips, Fluke A3001 FC Wireless

iFlex AC Current Module, iFlex I2500-10 Flexible Current Probe, TL175 Test Leads

FETV3001FC-KIT

FETA3001FC-KIT

FETA3000FC-KIT

Safety Rating

Ground Resistance Range

Current Measurement Range Data Logging Jaw Capacity Includes

Item

No. Clamp On Earth Resistance Tester

CAT IV 600V, CAT III 1,000V 0.025 - 1,500 Ω 0.2 mA to 40.0 A 32,760 Records 1.5 in (40 mm) Earth Ground Clamp, Hard Case, Batteries, Safety

Information Guide, Quick Reference Guide FETFLUKE16302FC