Split-Bolt Connectors Highly resistant to cracking and corrosion. Provide maximum pressure and a secure connection on all combinations of run and tap conductors.

WWG22A931

Wire Range w/Equal Main and Tap (AWG)

Min. Tap Conductor w/1 Max. Main (AWG)

Item

No. 2 Stranded to 2/0 Stranded 14 str WWG22A938 4 Stranded to 1/0 Stranded 14 str WWG22A935 6 Stranded to 2 Stranded 14 str WWG22A931 8 Stranded to 4 Solid 14 str WWG22A933 1/0 Stranded to 350 kcmil 1/0 str WWG22A942 2/0 Stranded to 500 kcmil 2/0 str WWG22A941 4/0 Stranded to 750 kcmil 4/0 str WWG22A943

BURNDY Mechanical Connectors

WWG22C199 WWG22C172

Min. Conductor Size Max. Conductor Size

No. of Conductors

Item

No. Mechanical Connectors

6 AWG Stranded 350 kcmil Stranded 1 WWG22C176 14 AWG Stranded 2 AWG Stranded 1 WWG22C172 6 AWG Stranded, 4 AWG Solid 300 kcmil Stranded, 4/0 AWG Solid 2 WWG22C196

2 AWG Stranded 600 kcmil Stranded 3 WWG22C207 2 AWG Stranded 600 kcmil Stranded 4 WWG22C198 1/0 AWG Stranded 750 kcmil Stranded 4 WWG22C199

BURNDY

2-Hole Compression Lugs

▪Rated for 600V to 35kV, 90°C applications Lugs withstand a wide range of electrical and environmental conditions, including current surges, extreme temperatures, corrosion, and vibration. Designed to operate cooler than the wire on which they are insulated. Electro-tin plated for corrosion resistance. Aluminum terminals come prefilled with PENTROX™ oxide inhibitor compound.

WWG22C332 Cable Size Stud Size Width Colour Code Die Code

Item

No. 6 AWG 1⁄4 in 0.46" Blue 374, 7 WWG22C357 500 kcmil 1⁄2 in 1.52" Brown 20, 299 WWG22C332 4/0 1⁄2 in 1.00" Purple 15 WWG22C334

BURNDY

Grounding Connectors

WWG22C051 WWG22C006 WWG22A958 WWG8TKU2

Wire Size

Grounding Wires

Connected To Wire Length Wire Length Brand

Item

No. Grounding Connectors

8 AWG to 750 kcmil 1⁄2 in to 1 in Pipe — — Burndy WWG22C051

Up to 1 in Braid 1 1⁄2 in Pipe, 1 5⁄8 in to 1 7⁄8 in Rod — — Burndy WWG22A986

10 AWG SOL, 12 to 1 AWG STR

5⁄8 in Rod — — Burndy WWG22A958

Coiled Grounding Wires

— — 10 ft 10 ft Approved Vendor WWG8TKU2 Static Discharge Clamps

— — — — Burndy WWG22C006

APPROVED VENDOR, BURNDY

RETRACT-A-CLAMP Self-Storing Static Discharge Cables

▪For static bonding and

grounding during the transfer of flammables ▪Neatly retracts out of the

way when not in use ▪Includes aluminum hand

clamp and 5⁄16" heavy- duty lug terminal ▪Self-coiling cable has

1⁄8" plated flexible steel construction with a high- visibility orange PVC coating LNDRAC10

Wire Length

Item

No. 5 ft LNDRAC5 10 ft LNDRAC10 15 ft LNDRAC15 20 ft LNDRAC10PLUS10 30 ft LNDRAC30

LIND EQUIPMENT

Terminal and Barrier Strips

▪Operating range: -40° to 302°F Feature heavy-duty, corrosion-resistant screws. Protective cover prevents contact with live terminals.

GGE6YH99

Amps Min. Wire Size Max. Wire Size Length Width Height

Item

No. 20 22 AWG 18 AWG 3.77" 0.64" 0.52" GGE6YH99 35 22 AWG 10 AWG 5.53" 0.93" 0.74" GGE6YJ02

APPROVED VENDOR