AMC 2026 catalogue

Pumps

Need a price? Log in or register at Grainger.ca 1658

PUMPS Flowmeters

Bag Filters

▪Reduce pump wear and maintenance ▪Filter can help you avoid costly

pump breakdowns Trap contaminants to help maintain your coolant filtration system with this CHIPBLASTER bag filter. For use with High Pressure Coolant Filter Systems

WWG35LZ81

Microns

Item

No. 5 WWG35LZ81 10 WWG35LZ82 25 WWG35LZ83 300 WWG35LZ84

CHIPBLASTER

Aluminum Air and Gas Flowmeters

▪Fluid temp. range: -20° to 240°F ▪Max. pressure: 1000 psi ▪Accuracy: ±2%, except where noted ▪Viton® seals Read in standard cu.-ft./min. (scfm); compensate for system pressures between 40 and 130 psi. Anodized aluminum body, piston, and cone. Install in any position, at any angle, even after 90° elbows; no need for special turbulence-reducing fittings.

WWG4NNC1

* ±7% accuracy.

For Pipe Size

Connection

Size

Connection

Type Flow Range Length

Item

No.

1⁄4 in 1⁄4 in NPTF 0.5 to 5 scfm 4 13⁄16" WWG4NNC1 * 1⁄4 in NPTF 2 to 20 scfm 4 13⁄16" WWG4NNC2 *

1⁄2 in

1⁄2 in NPTF 3 to 25 scfm 6 5⁄8" WWG4NNC4 1⁄2 in NPTF 5 to 50 scfm 6 5⁄8" WWG4NNC5 1⁄2 in NPTF 10 to 100 scfm 6 5⁄8" WWG4NNC6

3⁄4 in 3⁄4 in NPTF 10 to 100 scfm 7 3⁄16" WWG4NNC7 3⁄4 in NPTF 25 to 250 scfm 7 3⁄16" WWG4NNC8

HEDLAND

Aluminum Oil Flowmeters

▪Fluid temp. range: -20° to 240°F ▪Max. pressure: 3500 psi ▪Accuracy: ±2% ▪Specific gravity: 0.876 ▪Viton® seals

WWG4NMV1

For Pipe Size Connection Size Flow Range Length

Item

No.

1⁄2 in 1⁄2 in

0.5 to 5 gpm

6 5⁄8"

WWG4NMW1 0.2 to 2 gpm WWG4NMV9 0.1 to 1 gpm WWG4NMV8 0.5 to 5 gpm WWG4NMV5 1 to 15 gpm WWG4NMW3

1 to 10 gpm WWG4NMW2

WWG4NMV6

1⁄4 in 1⁄4 in .05 to 0.5 gpm 4 13⁄16" WWG4NMV1 0.2 to 2 gpm WWG4NMV3

3⁄4 in 3⁄4 in

1 to 10 gpm

7 3⁄16"

WWG4NMW9

2 to 20 gpm WWG4NMX1 WWG4NMW6 3 to 30 gpm WWG4NMX2

1 1⁄4 in 1 1⁄4 in 5 to 50 gpm 12 3⁄16" WWG4NND5 10 to 100 gpm WWG4NND4

1 in 1 in

2 to 20 gpm

7 3⁄16"

WWG4NMX6 3 to 30 gpm WWG4NMX7 4 to 40 gpm WWG4NMX8

5 to 50 gpm WWG4NMX4 WWG4NMX9

HEDLAND

Aluminum Water- Based Flowmeters

▪Fluid temp. range: -20° to 240°F ▪Max. pressure: 3500 psi ▪Viton® seals Direct-reading scale and guard can be rotated 360°. Install in any position.

WWG4NMY6

For Pipe Size

Connection

Size

Connection

Type Flow Range Length Accuracy (%)

Item

No.

1⁄4 in 1⁄4 in

NPTF

0.1 to 1 gpm 4 13⁄16" ±7% Full Scale WWG4NMY6

1⁄2 in 1⁄2 in 0.2 to 2 gpm 6 5⁄8" ±2% Full Scale

WWG4NMY8 1 to 15 gpm WWG4NMZ2

3⁄4 in 3⁄4 in 2 to 20 gpm 7 3⁄16" WWG4NMZ3 3 to 30 gpm WWG4NMZ4

HEDLAND

Pulse Mechanical Flowmeter

▪Fluid temp. range: 35° F - 105° F ▪Max. pressure: 150 PSI ▪Accuracy: ±1.5% Designed for use in conjunction with a pulse timer to proportionally control pumps and valves, this rugged PULSAFEEDER mechanical flowmeter is suitable for water treatment in cooling tower systems, boiler systems, water chlorination, washes, and other industrial applications which need proportional control. Meter can maintain accuracy over a wide range of flows with low head loss.

WWG3FKP4

For Pipe Size

Connection

Size

Connection

Type Flow Range Length

Item

No.

3⁄4 in to 2 in

3⁄4 in NPT

0.22 to 22 gpm 12 5⁄8" WWG3FKP4 WWG3FKP5

1 1⁄2 in 0.88 to 88 gpm 17 5⁄8" WWG3FKP8

SEAMETRICS