AMC 2026 catalogue

Pneumatics

Air Compressors

Find even MORE at Grainger.ca 1605

1-888-602-0000 PNEUMATICS

Single-Stage Tank Mounted Air Compressors SPEEDAIRE®

▪Tanks have safety valve, pressure gauge, and manual tank drain ▪Thermally protected single-phase motors do not require a starter ▪Cycle On/Off while providing continuous air with an 80/20 duty cycle

INGERSOLL RAND®

▪Hardened steel crank shaft with precision bearings ▪Splash lubrication ▪Continuous duty ▪Must be hardwired SDR4ME98 SDR4B234 IRGSS3L3-23-1

HP

Free Air CFM @ Max.

Pressure Max. Pressure Phase Input Voltage Amps (F)NPT Outlet

Overall Length

Overall

Width

Overall

Height Brand

Item

No. Vertical

3.00 — 135 PSI 1 240V AC 14.7 1⁄2" 20 in 23 in 66 in Ingersoll Rand IRGSS3L3 10.2 135 PSI 1 240V AC 15.7 A 3⁄4" 23 in 25 in 66 in Speedaire SDR4ME96 10.3 — — 240V AC 14.7 A 3⁄8" 20 in 23 in 66 in Ingersoll Rand IRGSS3L3-23-1

5.00 14.2 140 PSI 3 208-240V AC, 480V AC 13.4-13.2/6.6 3⁄4" 23 in 31 in 71 in Speedaire SDR4ME98 14.2 140 PSI 1 230V AC 21 3⁄4" 23 in 31 in 71 in Speedaire SDRTQ3122 15.5 — — 230V AC 21.5 A 1⁄2" 20 in 30 in 71 in Ingersoll Rand IRGSS5L5-23-1 Horizontal

2.00 4.9 135 PSI 1 120V AC, 240V AC 15/7.5 A 1⁄4" 40.62 in 21.62 in 38 in Speedaire SDR4B234

INGERSOLL RAND, SPEEDAIRE

Two-Stage Stationary Electric Air Compressors 100% cast iron, continuous duty cycle. Totally enclosed, beltguard. Stainless steel finger valve prolongs service intervals. Single point electrical connection, auto start/stop control factory setting 145-175 PSI. ASME tank with manual drain, discharge isolation ball valve and relief valve. V-cylinder design for ease of maintenance and maximum compressor start feature prolongs motor life, splash lubrication. Interstage relief valve and discharge valve. Single phase 5 HP compressor features a capacitor start, thermally protected motor requiring no magnetic starter. 3 phase, 5, 7.5, 10 and 15 HP compressors include factory mounted magnetic motors.

IRG2545E10VS20-3 RG2340L5-23-1

HP Rating

Free Air CFM

@ 175 PSI Volts Phase Amperage Draw

Tank Size (gal.)

NPTF Outlet (in.) Includes Item No.

5

14 230* Single 28.0 60 V 1⁄2 Manual Drain Valve, Pressure Gauge, Pressure Safety Valve IRG2340L5-23-1 14 230* Three 15.2 60 V 1⁄2 Manual Drain Valve, Motor Starter, Pressure Gauge, Pressure Safety Valve IRG2340L5V23-3

16.8 230* Single 28.0 80 V 1⁄2 Air Cooled Aftercooler, Electronic Drain Valve, Low Oil Protection

Switch, Motor Starter, Pressure Gauge, Pressure Safety Valve IRG2475N5S23-1

16.8 575* Three 6.1 80 V 1⁄2 Automatic Start/Stop Control with Pressure Switch and Manual

Drain, Magnetic Motor Starter, ODP Motor, Receiver Tank

IRG2475N5S57-3 16.8 230* Three 15.2 80 V 1⁄2 IRG2475N5V23-3

7 1⁄2

24 230* Single 40.0 80 V 1⁄2 Manual Drain Valve, Motor Starter, Pressure Gauge, Pressure Safety Valve

IRG2475N7.5S23-1 24 230* Three 22.0 80 V 1⁄2 IRG2475N7.5S23-3 24 460* Three 11.0 80 V 1⁄2 IRG2475N7.5S46-3

24 575* Three 9.0 80 V 1⁄2 Air-Cooled Aftercooler, Automatic Start/Stop Control with Pressure Switch and Manual Drain, Electric Drain, Low Oil Level

Switch, Magnetic Motor Starter, ODP Motor, Receiver Tank

IRG2475N7.5S57-3

10

35 200 Three 30.6 120 H 3⁄4 Manual Drain Valve, Motor Starter, Oil Sight Glass,

Pressure Gauge, Pressure Safety Valve IRG2545E10VS20-3

35 575* Three 11.0 120 H 3⁄4 Air Receiver Tank, ODP Electric Motor, Pressure Switch IRG2545E10VS575-3

35 200 Three 30.6 120 V 3⁄4 Manual Drain Valve, Motor Starter, Oil Sight Glass,

Pressure Gauge, Pressure Safety Valve IRG2545K10VS20-3

35 575* Three 11.0 120 V 3⁄4 Air Receiver Tank, ODP Electric Motor, Pressure Switch IRG2545K10VS575-3

15 50 200 Three 48.3 120 H 1 Low Oil Protection Switch, Manual Drain Valve,

Pressure Gauge, Pressure Safety Valve IRG7100E15VS20-3

INGERSOLL RAND

Two-Stage Duplex Air Compressors

▪Low rpm for long service life ▪Must be hardwired ▪Fully enclosed belt guard ▪Expected pump life: 15,000 hr. ▪Max. pressure: 175 psi

Allow you to maximize energy efficiency by automatically alternating between 2 compressors or by operating both simultaneously.

SDR7DC51

HP Tank Size

Free Air CFM @ Max. Pressure Phase Input Voltage Amps Overall Length Overall Width Overall Height

Item

No. Milwaukee

5 X 2 120 gal 32.8 1 208 - 240 VAC 44 A 69 in 32 in 51 in SDR7DC51 120 gal 32.8 3 208 - 230VAC, 460VAC 14.2 A - 12.8/6.4 A 69 in 32 in 51 in SDR7DC53 Brentwood Industries

7.5 X 2 120 gal 49.0 1 208 - 240 VAC 62 A 69 in 32 in 51 in SDR7DC71 120 gal 49.0 3 208 - 230VAC, 460VAC 19.8 A - 17.9/8.9 A 69 in 32 in 51 in SDR7DC73 Dayton

10 X 2 200 gal 72.0 3 208 - 230VAC, 460VAC 27 A - 24.4/12.2 A 91 in 32 in 60 in SDR7DC10 15 X 2 200 gal 100 3 208 - 230VAC, 460VAC 41.1 A - 37.2/18.6 A 91 in 32 in 60 in SDR7DC15

BRENTWOOD INDUSTRIES, DAYTON, MILWAUKEE

* Service available through your nearest Acklands-Grainger location.